DIGITAL CLAMP METER 400A
€129,00
Out of stock
The digital clamp meter UT203R is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A and frequencies from 10Hz to 60kHz for low voltage up to 600V and 10Hz to 10MHz for low voltage. On all ranges, it has protection against voltages greater than 600V and an audible and optical alarm. Four-digit multi-segment display with a size of 37 x 25 mm with a backlight and a fast refresh rate 3 times/s. Opening the jaws allows measurement on cables with a diameter of up to 28 mm. Non-contact sensing of the electric field NCV makes it possible to detect live conductors in two sensitivities – EFLo and – EFHi for low voltage 110V/50/60Hz and 230V/50/60Hz distributions. The attached probe – the cover of the tips on the test cables enables measurements on LV distributions in the CAT III category without the risk of arcing. Without covers on the tips, test cables can only be measured on CAT II LV distributions. Power battery 2 pcs 1.5V R03. The power consumption of the meter is approx. 1.8 mA. The circuit has an automatic energy saving function. Sleep mode consumption is 11μA, which effectively extends the battery life to about 400 hours.
Product parameters:
– measurement of voltage, current and frequency of high voltage up to 600 V
– measurement of frequencies 10Hz to 10MHz
– measurement of capacities 6nF to 60mF
– temperature measurement -40 to +1000°C
– proportional relative measurement of voltage and capacity
– multi-segment display and audio/visual alarm
– protection against voltages greater than 600V across ranges
– non-contact detection of live wires
– automatic range switching
– current and voltage measurement accuracy is guaranteed within 1 to 100 of ranges
Technical parameters:
1. AC current measurement ranges / resolution / accuracy :
40.00A / 0.010A / 50Hz ~ 100Hz ±2.0+5
400.0A / 0.100A / 50Hz ~ 100Hz ±2.0+5
– frequency monitoring accuracy when measuring AC current in the range of 50 to 100Hz is ±1.0+5 at a resolution of 0.1Hz
– overload protection at 420A
2. DC current measurement ranges / resolution / accuracy:
40.00A / 0.010A / ±2.0+5
400.0A / 0.100A / ±2.0+5
– overload protection at 420A
3. AC voltage measurement range / resolution / accuracy :
4.000V / 0.001V / 10Hz ~ 10kHz ±1.0+5
40.00V / 0.010V / 10Hz ~ 10kHz ±0.8+5
400.0V / 0.100V / 10Hz ~ 10kHz ±0.8 +5
600.0V / 1V / 10Hz ~ 10kHz ±0.8+5
– accuracy of frequency monitoring when measuring AC voltage in the range of 10Hz to 60kHz ±0.5+2 at a resolution of 0.01Hz to 0.01kHz
– overload protection at 600Vrms
– input impedance approx. 10MΩ
4. DC voltage measurement range / resolution / accuracy :
400.0mV / 0.100mV / ±0.7+3
4.000V / 0.001V / ±0.5+2
40 .00V / 0.010V / ±0.5+2
400.0V / 0.100V / ±0.5+2
600.0V / 1V / ±0.5+2
– input impedance approx . 10MΩ
– overload protection at 600Vrms
5. Resistance measurement ranges / resolution / accuracy :
400.0Ω / 0.1Ω / ±1.0+2
4.000kΩ / 0.001kΩ / ±0.8+2
40.00kΩ / 0.01kΩ / ±0.8+2
400.0kΩ / 0.1kΩ / ±0.8+2
4.000MΩ / 0.001MΩ / ±2.5+5
40.00MΩ / 0.01MΩ / ±2.5+5
– overload protection at 600 Vrms
– open circuit voltage approx. 1V
6. Capacitance measurement ranges / resolution / accuracy :
40.00nF / 0.01nF / ±4.0+5
400.0nF / 0.1nF / ±4.0+5
4.000μF / 0.001 μF / ±4.0+5
40.00μF / 0.01μF / ±4.0+5
400.0μF / 0.1μF / ±4.0+5
4.000mF / 0.001mF / ±10.0
40.00mF / 0.01mF / ±10.0
– overload protection at 600 Vrms
7. Measurement of frequency and filling ranges / resolution / accuracy :
frequency: 10Hz to 10MHz / 0.01Hz to 0.01MHz / ±0.1 + 4
filling: 0.1 to 99.9 / 0.1 / ±3.0 + 5
– Note 1 Measurement sensitivity:
≤100kHz : 200mVrms ≤ input amplitude ≤ 30V RMS
100kHz~1MHz : 600mV RMS ≤ input amplitude ≤ 30V RMS
1MHz~10MHz : 1V RMS ≤ input amplitude ≤ 30V RMS
– Note 2 The duty ratio measurement is only applicable for square wave ≤10kHz, amplitude: 1V pp
Frequency ≤ 1kHz Duty ratio Duty: 10.0~95.0
Frequency 1kHz Duty ratio Duty: 30.0~70.0
– overload protection at 600 Vrms
8. Checking the continuity of circuits:
– if the measured resistance is less than 10Ω, the signal of a continuous circuit will sound, the buzzer will sound
– if the measured resistance is greater than 31Ω, the signal of the open circuit will not sound
– the uncertainty in the range of 10Ω to 31Ω
– the voltage of the open circuit approx. 2.0V
– measurement on the 600Ω range
– overload protection at 600 Vrms
9. Measurement of diodes:
– in the forward direction, the voltage drop of the semiconductor junction is less than or equal to 2V
– a voltage drop of 0.5 to 0.8V is typical for a silicon junction
– an open circuit voltage of about 4.0V
– measurement on a range of 6,000V
10. Non-contact sensing of the electric field NCV:
– allows detection of live conductors in two sensitivities -EFLo and – EFHi for nn 110V/50/60Hz and 230V/50/60Hz distributions
Other parameters:
– measurement of maximum and minimum values: yes
– measurement in relative ratio mode for measuring voltage and capacity: yes
– retention of data HOLD : yes
– low battery indication: yes
– automatic power off: yes
– 1.5V battery power R03: 2pcs
– backlit display size: 37mm x 25mm
– product dimensions: 215mm x 63mm x 36mm
– product net weight: 235 g
– product color: red and gray
Package contents:
– clamp multimeter UT203R: 1pc
– test leads: 1 pair
– battery 1.5V R03: 2pc
– instruction manual: 1pc
Wholesale package:
– standard quantity per carton: 40 pcs
– standard carton dimensions: 485 mm x 295 mm x 385 mm
– standard gross carton weight: 16.1 kg
The digital clamp meter UT203R is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A and frequencies from 10Hz to 60kHz for low voltage up to 600V and 10Hz to 10MHz for low voltage. On all ranges, it has protection against voltages greater than 600V and an audible and optical alarm. Four-digit multi-segment display with a size of 37 x 25 mm with a backlight and a fast refresh rate 3 times/s. Opening the jaws allows measurement on cables with a diameter of up to 28 mm. Non-contact sensing of the electric field NCV makes it possible to detect live conductors in two sensitivities - EFLo and - EFHi for low voltage 110V/50/60Hz and 230V/50/60Hz distributions. The attached probe - the cover of the tips on the test cables enables measurements on LV distributions in the CAT III category without the risk of arcing. Without covers on the tips, test cables can only be measured on CAT II LV distributions. Power battery 2 pcs 1.5V R03. The power consumption of the meter is approx. 1.8 mA. The circuit has an automatic energy saving function. Sleep mode consumption is 11μA, which effectively extends the battery life to about 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- measurement of frequencies 10Hz to 10MHz
- measurement of capacities 6nF to 60mF
- temperature measurement -40 to +1000°C
- proportional relative measurement of voltage and capacity
- multi-segment display and audio/visual alarm
- protection against voltages greater than 600V across ranges
- non-contact detection of live wires
- automatic range switching
- current and voltage measurement accuracy is guaranteed within 1 to 100 of ranges
Technical parameters:
1. AC current measurement ranges / resolution / accuracy :
40.00A / 0.010A / 50Hz ~ 100Hz ±2.0+5
400.0A / 0.100A / 50Hz ~ 100Hz ±2.0+5
- frequency monitoring accuracy when measuring AC current in the range of 50 to 100Hz is ±1.0+5 at a resolution of 0.1Hz
- overload protection at 420A
2. DC current measurement ranges / resolution / accuracy:
40.00A / 0.010A / ±2.0+5
400.0A / 0.100A / ±2.0+5
- overload protection at 420A
3. AC voltage measurement range / resolution / accuracy :
4.000V / 0.001V / 10Hz ~ 10kHz ±1.0+5
40.00V / 0.010V / 10Hz ~ 10kHz ±0.8+5
400.0V / 0.100V / 10Hz ~ 10kHz ±0.8 +5
600.0V / 1V / 10Hz ~ 10kHz ±0.8+5
- accuracy of frequency monitoring when measuring AC voltage in the range of 10Hz to 60kHz ±0.5+2 at a resolution of 0.01Hz to 0.01kHz
- overload protection at 600Vrms
- input impedance approx. 10MΩ
4. DC voltage measurement range / resolution / accuracy :
400.0mV / 0.100mV / ±0.7+3
4.000V / 0.001V / ±0.5+2
40 .00V / 0.010V / ±0.5+2
400.0V / 0.100V / ±0.5+2
600.0V / 1V / ±0.5+2
- input impedance approx . 10MΩ
- overload protection at 600Vrms
5. Resistance measurement ranges / resolution / accuracy :
400.0Ω / 0.1Ω / ±1.0+2
4.000kΩ / 0.001kΩ / ±0.8+2
40.00kΩ / 0.01kΩ / ±0.8+2
400.0kΩ / 0.1kΩ / ±0.8+2
4.000MΩ / 0.001MΩ / ±2.5+5
40.00MΩ / 0.01MΩ / ±2.5+5
- overload protection at 600 Vrms
- open circuit voltage approx. 1V
6. Capacitance measurement ranges / resolution / accuracy :
40.00nF / 0.01nF / ±4.0+5
400.0nF / 0.1nF / ±4.0+5
4.000μF / 0.001 μF / ±4.0+5
40.00μF / 0.01μF / ±4.0+5
400.0μF / 0.1μF / ±4.0+5
4.000mF / 0.001mF / ±10.0
40.00mF / 0.01mF / ±10.0
- overload protection at 600 Vrms
7. Measurement of frequency and filling ranges / resolution / accuracy :
frequency: 10Hz to 10MHz / 0.01Hz to 0.01MHz / ±0.1 + 4
filling: 0.1 to 99.9 / 0.1 / ±3.0 + 5
- Note 1 Measurement sensitivity:
≤100kHz : 200mVrms ≤ input amplitude ≤ 30V RMS
100kHz~1MHz : 600mV RMS ≤ input amplitude ≤ 30V RMS
1MHz~10MHz : 1V RMS ≤ input amplitude ≤ 30V RMS
- Note 2 The duty ratio measurement is only applicable for square wave ≤10kHz, amplitude: 1V pp
Frequency ≤ 1kHz Duty ratio Duty: 10.0~95.0
Frequency 1kHz Duty ratio Duty: 30.0~70.0
- overload protection at 600 Vrms
8. Checking the continuity of circuits:
- if the measured resistance is less than 10Ω, the signal of a continuous circuit will sound, the buzzer will sound
- if the measured resistance is greater than 31Ω, the signal of the open circuit will not sound
- the uncertainty in the range of 10Ω to 31Ω
- the voltage of the open circuit approx. 2.0V
- measurement on the 600Ω range
- overload protection at 600 Vrms
9. Measurement of diodes:
- in the forward direction, the voltage drop of the semiconductor junction is less than or equal to 2V
- a voltage drop of 0.5 to 0.8V is typical for a silicon junction
- an open circuit voltage of about 4.0V
- measurement on a range of 6,000V
10. Non-contact sensing of the electric field NCV:
- allows detection of live conductors in two sensitivities -EFLo and - EFHi for nn 110V/50/60Hz and 230V/50/60Hz distributions
Other parameters:
- measurement of maximum and minimum values: yes
- measurement in relative ratio mode for measuring voltage and capacity: yes
- retention of data HOLD : yes
- low battery indication: yes
- automatic power off: yes
- 1.5V battery power R03: 2pcs
- backlit display size: 37mm x 25mm
- product dimensions: 215mm x 63mm x 36mm
- product net weight: 235 g
- product color: red and gray
Package contents:
- clamp multimeter UT203R: 1pc
- test leads: 1 pair
- battery 1.5V R03: 2pc
- instruction manual: 1pc
Wholesale package:
- standard quantity per carton: 40 pcs
- standard carton dimensions: 485 mm x 295 mm x 385 mm
- standard gross carton weight: 16.1 kg
